S7-300 to S7-1500
Spares only since Oct 1, 2025
S7-300 to S7-1500Siemens moved the S7-300 to spares-only on Oct 1, 2025. Rockwell discontinued the remaining PLC-5 processors in 2017 and lists several SLC 500 controllers as discontinued. If your lines still run on them, the question is when you migrate, not whether.
We start with an audit that tells you where you stand: what controllers you have, how exposed each line is if a card fails, and a staged plan to migrate during planned downtime, with a fallback to the old rack if anything goes sideways.
Illustrative model
Spares only
Siemens S7-300 and ET 200M have been spare parts only since October 1, 2025.
Source: Siemens, Oct 1, 2025
Discontinued
Rockwell discontinued the remaining PLC-5 processors in 2017. RSLogix 5 reached the end of its life cycle at the end of 2025.
Source: Rockwell, 2017; Rockwell, Dec 31, 2025
Partly discontinued
Rockwell lists several SLC 500 processors as discontinued and points new systems at CompactLogix.
Source: Rockwell
The plan is yours. If you want us to do the work, we quote it from the hours it actually takes.
See also: Outage-window planning, Program backup and version control
Spares only since Oct 1, 2025
S7-300 to S7-1500Staged around outages
Step 5 and STEP 7 to TIA PortalDiscontinued in 2017
PLC-5 to ControlLogixPartly discontinued
SLC 500 to CompactLogixA written cutover plan for the shutdown window
Outage planningFlags discontinued parts and the spares to stock
Spare parts and obsolescenceModeled best case
Modeled area: four lines on S7-300, PLC-5 and SLC 500, audited first, then migrated one line per planned outage.
Before: 3After: 0
Each migrated line runs on a current CPU, with a spare stocked for it.
Before: 2After: 0
Each cutover ends with the backups brought up to date, so every line ends with a backup that matches what is running.
Before: 9 hAfter: 1 h
Aging racks and cards come out one line at a time, so fewer failures stop a line between outages.
Illustrative figures for the line, cell or area described, when everything goes right. They are not measured, not from any plant we have supported, not typical, and not a promise. A real job starts from your own baseline.
No. You can go line by line, starting with the most exposed one.
Yes. We read what is running, document it, and convert it. Messy legacy code is normal.
That is why every plan has a fallback to the old rack until the new one is proven.
Yes. Evaluations happen at the machine so the first trip is not a guessing trip.
Send the plant, the controllers on each line, and your next shutdown. We come back with an audit plan, not a brochure.